{"id":12336,"date":"2024-09-05T19:36:32","date_gmt":"2024-09-06T03:36:32","guid":{"rendered":"https:\/\/omchsmps.com\/?p=12336"},"modified":"2024-09-05T19:36:32","modified_gmt":"2024-09-06T03:36:32","slug":"npn-ve-pnp-yakinlik-sensorleri","status":"publish","type":"post","link":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/","title":{"rendered":"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri"},"content":{"rendered":"

Yak\u0131nl\u0131k sens\u00f6rleri, fiziksel temas olmaks\u0131z\u0131n nesneleri alg\u0131lamak i\u00e7in kullan\u0131l\u0131r. 2 telli ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri vard\u0131r ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri daha pop\u00fclerdir. \u00c7\u0131k\u0131\u015f t\u00fcrlerine g\u00f6re iki ana yak\u0131nl\u0131k sens\u00f6r\u00fc t\u00fcr\u00fc vard\u0131r:\u00a0NPN<\/strong>\u00a0ve\u00a0PNP<\/strong>.<\/p>\n

Belirli bir uygulama i\u00e7in do\u011fru yak\u0131nl\u0131k sens\u00f6r\u00fc tipini se\u00e7mek, bir sistemin do\u011fru \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flayabilir. Bu makale, iki ana \u00e7\u0131k\u0131\u015f t\u00fcr\u00fcn\u00fcn ana hatlar\u0131n\u0131 ve bir yak\u0131nl\u0131k sens\u00f6r\u00fcn\u00fcn bir PLC'ye nas\u0131l ba\u011flanaca\u011f\u0131 konusunda bir k\u0131lavuz sa\u011flamay\u0131 ama\u00e7lamaktad\u0131r.<\/p>\n

NPN yak\u0131nl\u0131k sens\u00f6r\u00fc nedir?<\/h2>\n

NPN yak\u0131nl\u0131k sens\u00f6rleri, aktif bir D\u00dc\u015e\u00dcK \u00e7\u0131k\u0131\u015f sa\u011flar. Bu, bir nesne sens\u00f6r\u00fcn alg\u0131lama aral\u0131\u011f\u0131na girdi\u011finde, sens\u00f6r\u00fcn \u00e7\u0131k\u0131\u015f\u0131n\u0131n topra\u011fa ba\u011fl\u0131 oldu\u011fu anlam\u0131na gelir. Bu sens\u00f6r tipi ayn\u0131 zamanda 'olarak da bilinir.batan<\/u><\/a>' sens\u00f6r.<\/p>\n

PNP yak\u0131nl\u0131k sens\u00f6r\u00fc nedir?<\/h2>\n

PNP yak\u0131nl\u0131k sens\u00f6rleri, aktif bir Y\u00dcKSEK \u00e7\u0131k\u0131\u015f sa\u011flar. Sens\u00f6r\u00fcn alg\u0131lama aral\u0131\u011f\u0131na bir nesne girdi\u011finde, sens\u00f6r\u00fcn \u00e7\u0131k\u0131\u015f\u0131 +24V ile ba\u011flan\u0131r. Bir PLC giri\u015fine ba\u011fland\u0131\u011f\u0131nda bunu bir mant\u0131k Y\u00dcKSEK sinyali olarak alg\u0131lar. PNP yak\u0131nl\u0131k sens\u00f6rleri ayn\u0131 zamanda 'olarak da bilinir.kaynak<\/u><\/a>' sens\u00f6rler.<\/p>\n

NPN ve PNP Sens\u00f6r Kablolar\u0131n\u0131 Hat\u0131rlaman\u0131n Bir Yolu<\/h2>\n

3 kablolu bir DC yak\u0131nl\u0131k sens\u00f6r\u00fcn\u00fcn kablolamas\u0131n\u0131 kolayca hat\u0131rlamak i\u00e7in a\u015fa\u011f\u0131daki benzetmeyi kullanabiliriz:<\/p>\n

P<\/u><\/strong>NP = Anahtarl\u0131\u00a0P<\/u><\/strong>ositiv<\/p>\n

N<\/u><\/strong>PN = Anahtarl\u0131\u00a0N<\/u><\/strong>egatif<\/p>\n

\"\"<\/p>\n

Yak\u0131nl\u0131k sens\u00f6rleri dijital sens\u00f6rlerdir. Bu nedenle, \u00e7al\u0131\u015fabilmeleri i\u00e7in her zaman 24V'luk bir g\u00fc\u00e7 kayna\u011f\u0131na ba\u011fl\u0131 olmalar\u0131 gerekir.<\/p>\n

PNP sens\u00f6r kablolamas\u0131nda y\u00fck\u00a0her zaman Negatif'e ba\u011fl\u0131.\u00a0<\/strong>Die\u00a0P<\/strong>yak\u0131nl\u0131k sens\u00f6r\u00fc bir nesne alg\u0131lad\u0131\u011f\u0131nda ositive de\u011fi\u015ftirilir. Ancak, NPN sens\u00f6r kablolamas\u0131nda y\u00fck\u00a0her zaman Pozitif'e ba\u011fl\u0131<\/strong>, Ve\u00a0N<\/strong>bir nesne alg\u0131land\u0131\u011f\u0131nda egative de\u011fi\u015ftirilir.<\/p>\n

Bir sens\u00f6r\u00fcn 3 kablolu ba\u011flant\u0131s\u0131 i\u00e7in PNP vs NPN<\/h2>\n

Hemen hemen t\u00fcm end\u00fcstriyel yak\u0131nl\u0131k sens\u00f6rleri kat\u0131 hal cihazlar\u0131d\u0131r, yani i\u00e7lerinde hareketli par\u00e7alar yoktur. En pop\u00fcler yak\u0131nl\u0131k sens\u00f6r\u00fc tipi 3 telli tiptir. Bir nesne alg\u0131land\u0131\u011f\u0131nda \u00e7\u0131k\u0131\u015f\u0131 de\u011fi\u015ftirmek i\u00e7in PNP veya NPN tipi transist\u00f6rler kullan\u0131rlar.<\/p>\n

Kablolardan ikisi sens\u00f6re \u00e7al\u0131\u015fma g\u00fcc\u00fc sa\u011flamak i\u00e7in kullan\u0131l\u0131rken, di\u011fer kablo sens\u00f6rden gelen \u00e7\u0131k\u0131\u015ft\u0131r.<\/p>\n

Bu noktada PNP veya NPN tipi bir sens\u00f6r oldu\u011funu belirtmekte fayda var.\u00a0de\u011fil<\/strong>\u00a0sens\u00f6r \u00e7\u0131k\u0131\u015f\u0131n\u0131n normalde a\u00e7\u0131k (N\/O) veya normalde kapal\u0131 (N\/C) oldu\u011funu g\u00f6sterir. Bu sadece uygulamaya ba\u011fl\u0131d\u0131r. (Yani, bir NPN N\/O veya N\/C olabilece\u011fi gibi, bir PNP sens\u00f6r\u00fc de N\/O veya N\/C olabilir)<\/p>\n

Bir r\u00f6lenin do\u011frudan bir yak\u0131nl\u0131k sens\u00f6r\u00fc taraf\u0131ndan \u00e7al\u0131\u015ft\u0131r\u0131ld\u0131\u011f\u0131 r\u00f6le tipi bir devreye bakal\u0131m.<\/p>\n

\"\"<\/p>\n

\u0130ki kablo aras\u0131ndaki fark, PNP tipi kablolamada r\u00f6lenin her zaman 0V'a ba\u011fl\u0131 olmas\u0131 ve +24V'nin sens\u00f6r taraf\u0131ndan anahtarlanmas\u0131d\u0131r. Ancak NPN tipi kablolamada r\u00f6le her zaman +24V'a ba\u011fl\u0131d\u0131r ve sens\u00f6r 0V ba\u011flant\u0131s\u0131n\u0131 de\u011fi\u015ftirir. Ne olursa olsun, sens\u00f6r ona g\u00fc\u00e7 sa\u011flamak i\u00e7in +24 ve 0V'a ba\u011flan\u0131r.<\/p>\n

NPN\/PNP Yak\u0131nl\u0131k Sens\u00f6r\u00fcn\u00fc PLC'ye Ba\u011flama<\/h2>\n

Uyar\u0131! Herhangi bir kablolama giri\u015fiminde bulunmadan \u00f6nce, elektrik \u00e7arpmas\u0131n\u0131 \u00f6nlemek i\u00e7in sistemin kapal\u0131 oldu\u011fundan emin olun.<\/em><\/p>\n

3 kablolu yak\u0131nl\u0131k sens\u00f6r\u00fcn\u00fcn renk kodunu belirleme<\/h3>\n

3 kablolu bir sens\u00f6rde kablo renk kodu a\u015fa\u011f\u0131daki gibidir: (Kahverengi: +24V, Mavi: 0V, Siyah: \u00e7\u0131k\u0131\u015f)<\/p>\n

\"\"<\/p>\n

Sens\u00f6r\u00fcn\u00fcz\u00fcn kablolar\u0131 farkl\u0131 renkteyse veya renk kodundan emin de\u011filseniz, l\u00fctfen \u00fcreticisinin veri sayfas\u0131na bak\u0131n.<\/p>\n

NPN tipi 3 kablolu yak\u0131nl\u0131k sens\u00f6r\u00fcn\u00fc bir PLC'ye ba\u011flama<\/h3>\n

Sens\u00f6r\u00fc PLC'ye ba\u011flamadan \u00f6nce, PLC'nin \u015fu \u015fekilde yap\u0131land\u0131r\u0131ld\u0131\u011f\u0131ndan emin olun.\u00a0'kaynak'\u00a0<\/strong>Hinweis. Siemens S7-200 PLC'de bu, 1M giri\u015fini +24V'a ba\u011flayarak yap\u0131labilir. Bu, PLC'nin giri\u015ften \"ak\u0131m kayna\u011f\u0131\" yapaca\u011f\u0131 ve NPN sens\u00f6r\u00fcn\u00fcn bir nesne alg\u0131lad\u0131\u011f\u0131nda \"ak\u0131m\u0131 d\u00fc\u015f\u00fcrece\u011fi\" anlam\u0131na gelir.<\/p>\n

Giri\u015f, bir giri\u015f kart\u0131 arac\u0131l\u0131\u011f\u0131yla PLC'ye besleniyorsa,\u00a0kaynak t\u00fcr\u00fc<\/strong>\u00a0giri\u015f kart\u0131 veya yap\u0131land\u0131r\u0131labilir bir kart. NS\u00a0SIMATIC S7-1200, Dijital Giri\u015f SB 1221<\/u><\/a>\u00a0b\u00f6yle bir kaynak t\u00fcr\u00fc giri\u015f kart\u0131d\u0131r.<\/p>\n

\"\"<\/p>\n

PNP tipi 3 kablolu yak\u0131nl\u0131k sens\u00f6r\u00fcn\u00fc bir PLC'ye ba\u011flama<\/h3>\n

PNP tipi bir sens\u00f6r i\u00e7in PLC'nin \u015fu \u015fekilde yap\u0131land\u0131r\u0131lmas\u0131 gerekir:\u00a0'batan'<\/strong>\u00a0tip. 1M giri\u015fini 0V'a ba\u011flamak, PLC'yi giri\u015f \u00e7\u00f6kmesi olarak yap\u0131land\u0131racakt\u0131r. Bu konfig\u00fcrasyonla, sens\u00f6r \"ak\u0131m kayna\u011f\u0131\" yapabilir ve PLC, sens\u00f6r \u00e7\u0131k\u0131\u015f\u0131n\u0131 alg\u0131lamak i\u00e7in \"ak\u0131m\u0131 d\u00fc\u015f\u00fcr\u00fcr\".<\/p>\n

PNP tipi bir yak\u0131nl\u0131k sens\u00f6r\u00fc i\u00e7in, bir giri\u015f kart\u0131 kullan\u0131l\u0131yorsa, bu bir ' olmal\u0131d\u0131r.batan<\/strong>‘\u00a0<\/em>kart\u0131 yaz\u0131n. NS\u00a0S7-1200, Dijital Giri\u015f SM 1221<\/u><\/a>\u00a0S7-1200 PLC'ler i\u00e7in giri\u015f kart\u0131, al\u0131c\u0131\/kaynak yap\u0131land\u0131r\u0131labilir bir giri\u015f kart\u0131d\u0131r ve her iki sens\u00f6r tipiyle aray\u00fcz olu\u015fturabilir.<\/p>\n

\"\"<\/p>\n

Bir PNP veya NPN sens\u00f6r\u00fc nas\u0131l se\u00e7ilir?<\/h2>\n

PNP ve NPN se\u00e7imi, \u00e7o\u011funlukla uygulamaya ve kullan\u0131labilirli\u011fe ba\u011fl\u0131d\u0131r. Olarak\u00a0ok Elektronik<\/u><\/a>\u00a0NPN sens\u00f6rlerinin Asya b\u00f6lgesindeki otomasyon end\u00fcstrisinde daha yayg\u0131n oldu\u011fundan bahseder. PNP sens\u00f6rleri Avrupa ve Amerika'da daha pop\u00fclerdir.<\/p>\n

NPN sens\u00f6rleri, PNP sens\u00f6rlerinden daha h\u0131zl\u0131 olduklar\u0131 i\u00e7in y\u00fcksek h\u0131zl\u0131 uygulamalarda kullan\u0131l\u0131r. Ayr\u0131ca r\u00f6le devrelerinde PLC devrelerinden daha fazla uygulama bulurlar. PNP sens\u00f6rleri, hasar g\u00f6rmesi ve toprakla k\u0131sa devre yapmas\u0131 durumunda yanl\u0131\u015f pozitif sinyalleri \u00f6nleyebildikleri i\u00e7in PLC devrelerinde daha pop\u00fclerdir.<\/p>\n

Yak\u0131nl\u0131k sens\u00f6r\u00fcm\u00fcn NPN mi yoksa PNP mi oldu\u011funu nas\u0131l anlar\u0131m?<\/h2>\n

Sens\u00f6r tipini belirlemenin en kolay yolu, sens\u00f6r\u00fcn g\u00f6vdesindeki etikete bakmakt\u0131r. Bu etiket bazen \u00fczerine bas\u0131l\u0131 bir ba\u011flant\u0131 \u015femas\u0131na da sahip olabilir.<\/p>\n

\"\"<\/p>\n

Sens\u00f6r i\u015faretli de\u011filse ve tak\u0131l\u0131ysa, bir multimetre sens\u00f6r tipinin belirlenmesine yard\u0131mc\u0131 olabilir. Sistemi a\u00e7\u0131n ve 0V ile siyah kablo aras\u0131ndaki voltaj\u0131 dikkatlice \u00f6l\u00e7\u00fcn. Sens\u00f6r aktifken +24V gerilim varsa PNP tipi sens\u00f6rd\u00fcr. Sens\u00f6r aktifken multimetrede 0V okuma varsa, bu b\u00fcy\u00fck olas\u0131l\u0131kla bir NPN sens\u00f6r\u00fcd\u00fcr.<\/p>\n

Sonu\u00e7<\/h2>\n

Bu yaz\u0131da, iki t\u00fcr yak\u0131nl\u0131k sens\u00f6r\u00fcn\u00fc, yap\u0131lar\u0131n\u0131 ve otomasyon sistemlerindeki uygulamalar\u0131n\u0131 tart\u0131\u015ft\u0131k. Sistemi m\u00fcmk\u00fcnse hem NPN hem de PNP tipi sens\u00f6rleri kullanabilecek \u015fekilde tasarlamak her zaman iyi bir uygulamad\u0131r. Bu, esneklik kontrollerini b\u00fcy\u00fck \u00f6l\u00e7\u00fcde art\u0131rabilir.<\/p>","protected":false},"excerpt":{"rendered":"

Yak\u0131nl\u0131k sens\u00f6rleri, fiziksel temas olmaks\u0131z\u0131n nesneleri alg\u0131lamak i\u00e7in kullan\u0131l\u0131r. 2 telli ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri vard\u0131r ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri daha pop\u00fclerdir. \u00c7\u0131k\u0131\u015f t\u00fcrlerine g\u00f6re iki ana yak\u0131nl\u0131k sens\u00f6r\u00fc t\u00fcr\u00fc vard\u0131r: NPN ve PNP. Belirli bir uygulama i\u00e7in do\u011fru yak\u0131nl\u0131k sens\u00f6r\u00fc tipini se\u00e7mek, bir sistemin do\u011fru \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flayabilir. Bu makale, iki ana \u00e7\u0131k\u0131\u015f t\u00fcr\u00fcn\u00fcn ana hatlar\u0131n\u0131 [...]<\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"yoast_head":"\nNPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri - OMCH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri\" \/>\n<meta property=\"og:description\" content=\"Yak\u0131nl\u0131k sens\u00f6rleri, fiziksel temas olmaks\u0131z\u0131n nesneleri alg\u0131lamak i\u00e7in kullan\u0131l\u0131r. 2 telli ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri vard\u0131r ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri daha pop\u00fclerdir. \u00c7\u0131k\u0131\u015f t\u00fcrlerine g\u00f6re iki ana yak\u0131nl\u0131k sens\u00f6r\u00fc t\u00fcr\u00fc vard\u0131r:\u00a0NPN\u00a0ve\u00a0PNP. Belirli bir uygulama i\u00e7in do\u011fru yak\u0131nl\u0131k sens\u00f6r\u00fc tipini se\u00e7mek, bir sistemin do\u011fru \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flayabilir. Bu makale, iki ana \u00e7\u0131k\u0131\u015f t\u00fcr\u00fcn\u00fcn ana hatlar\u0131n\u0131 […]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/\" \/>\n<meta property=\"og:site_name\" content=\"OMCH\" \/>\n<meta property=\"article:published_time\" content=\"2024-09-06T03:36:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.omchsmps.com\/wp-content\/uploads\/2021\/08\/NPN-and-PNP-proximity-sensors-01.jpg\" \/>\n<meta name=\"author\" content=\"joe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"joe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/\",\"url\":\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/\",\"name\":\"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri - OMCH\",\"isPartOf\":{\"@id\":\"https:\/\/omchsmps.com\/#website\"},\"datePublished\":\"2024-09-06T03:36:32+00:00\",\"dateModified\":\"2024-09-06T03:36:32+00:00\",\"author\":{\"@id\":\"https:\/\/omchsmps.com\/#\/schema\/person\/109ef3adfc5831646d98fcb23c9d2226\"},\"breadcrumb\":{\"@id\":\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/omchsmps.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/omchsmps.com\/#website\",\"url\":\"https:\/\/omchsmps.com\/\",\"name\":\"OMCH\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/omchsmps.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/omchsmps.com\/#\/schema\/person\/109ef3adfc5831646d98fcb23c9d2226\",\"name\":\"joe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/omchsmps.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/636f6f3ffa6ace19dd4ae8170110efdc?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/636f6f3ffa6ace19dd4ae8170110efdc?s=96&d=mm&r=g\",\"caption\":\"joe\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri - OMCH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/","og_locale":"de_DE","og_type":"article","og_title":"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri","og_description":"Yak\u0131nl\u0131k sens\u00f6rleri, fiziksel temas olmaks\u0131z\u0131n nesneleri alg\u0131lamak i\u00e7in kullan\u0131l\u0131r. 2 telli ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri vard\u0131r ve 3 telli yak\u0131nl\u0131k sens\u00f6rleri daha pop\u00fclerdir. \u00c7\u0131k\u0131\u015f t\u00fcrlerine g\u00f6re iki ana yak\u0131nl\u0131k sens\u00f6r\u00fc t\u00fcr\u00fc vard\u0131r:\u00a0NPN\u00a0ve\u00a0PNP. Belirli bir uygulama i\u00e7in do\u011fru yak\u0131nl\u0131k sens\u00f6r\u00fc tipini se\u00e7mek, bir sistemin do\u011fru \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flayabilir. Bu makale, iki ana \u00e7\u0131k\u0131\u015f t\u00fcr\u00fcn\u00fcn ana hatlar\u0131n\u0131 […]","og_url":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/","og_site_name":"OMCH","article_published_time":"2024-09-06T03:36:32+00:00","og_image":[{"url":"https:\/\/www.omchsmps.com\/wp-content\/uploads\/2021\/08\/NPN-and-PNP-proximity-sensors-01.jpg"}],"author":"joe","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"joe","Gesch\u00e4tzte Lesezeit":"6\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/","url":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/","name":"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri - OMCH","isPartOf":{"@id":"https:\/\/omchsmps.com\/#website"},"datePublished":"2024-09-06T03:36:32+00:00","dateModified":"2024-09-06T03:36:32+00:00","author":{"@id":"https:\/\/omchsmps.com\/#\/schema\/person\/109ef3adfc5831646d98fcb23c9d2226"},"breadcrumb":{"@id":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/omchsmps.com\/de\/npn-ve-pnp-yakinlik-sensorleri\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/omchsmps.com\/"},{"@type":"ListItem","position":2,"name":"NPN ve PNP yak\u0131nl\u0131k sens\u00f6rleri"}]},{"@type":"WebSite","@id":"https:\/\/omchsmps.com\/#website","url":"https:\/\/omchsmps.com\/","name":"OMCH","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/omchsmps.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/omchsmps.com\/#\/schema\/person\/109ef3adfc5831646d98fcb23c9d2226","name":"joe","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/omchsmps.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/636f6f3ffa6ace19dd4ae8170110efdc?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/636f6f3ffa6ace19dd4ae8170110efdc?s=96&d=mm&r=g","caption":"joe"}}]}},"_links":{"self":[{"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/posts\/12336"}],"collection":[{"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/comments?post=12336"}],"version-history":[{"count":1,"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/posts\/12336\/revisions"}],"predecessor-version":[{"id":12337,"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/posts\/12336\/revisions\/12337"}],"wp:attachment":[{"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/media?parent=12336"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/categories?post=12336"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/omchsmps.com\/de\/wp-json\/wp\/v2\/tags?post=12336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}